| This instruction show you guide on how to calibrate 1001 Crossgate Lever for Fendt Vario 700 S4 tractor.
Related Contents:
[URL=https://www.autoepccatalog.com/product/fendt-fendias-with-eol-diagnostic-sof tware-highest-level/]FENDT Fendias 2024 Diagnostic software[/URL] [URL=https://www.autoepccatalog.com/product/agco-2x4-canusb-diagnostic-kit-f or-agco-agricultural-machine/]AGCO 2x4 CANUSB[/URL]
Procedures: Apply the hand brake Switch on ignition. Press to confirm any existing errors displayed in the instrument cluster Press to display the first main menu level Press until symbol A flashes Press to display the second main menu level Press until symbol A flashes Press to display the auxiliary spool valve menu level Press until symbol A flashes Press to be able to enter the calibration code Press and enter code 1001 Confirm with Release crossgate lever ? it centers automatically Confirm with Push and hold the crossgate lever fully right (with the spring) Confirm with Push and hold the crossgate lever fully left (with the spring) Confirm with Push and hold the crossgate lever fully forwards (with the spring) Confirm with Push and hold the crossgate lever fully backwards (with the spring) Confirm with Push and hold the crossgate lever fully right (with the spring) In this position, push and hold the crossgate lever fully forwards (with the spring) Confirm with Push and hold the crossgate lever fully right (with the spring) In this position, push and hold the crossgate lever fully backwards (with the spring) Confirm with Push and hold the crossgate lever fully left (with the spring) In this position, push and hold the crossgate lever fully backwards (with the spring) Confirm with Push and hold the crossgate lever fully left (with the spring) In this position, push and hold the crossgate lever fully forwards (with the spring) Confirm with Push and hold the crossgate lever fully right (not with the spring) Confirm with Push and hold the crossgate lever fully left (not with the spring) Confirm with Push and hold the crossgate lever fully forwards (not with the spring) Confirm with Push and hold the crossgate lever fully backwards (not with the spring) Confirm with If calibration is error-free, OK appears and the calibration values are stored Note: The values are not applied until after a key reset. Wait at least 60 seconds before switching the ignition ON. If incorrect values are detected or the conditions were not met, ERROR appears 1001 Calibration code FXX Fault code
[URL=https://www.car-auto-repair.com ]https://www.car-auto-repair.com [/URL] |
| Recently Spotted MembersNo members found. Be the first. |